Load Panel Warning Message: Please Confirm ASVersion

This warning emerges on the Data Process Control Load Panel usually after an upgrade to BPM Connect, or, a change in the underlying SQL Server platform.

This is an example of the exact message:





This warning is an indicator the Data Process control is not matching the underlying SQL Server version from which it is dependent, thus risking behavior problems.

The remedy to this problem is to adjust the ASVersion setting in BPM Connect to match the correct version of SQL Server.  

To access this setting, go to BPM Connect Config Builder -> Settings -> Global Configurations -> ASVersion. 

NOTE:  There has been a documented problem in DBObjects 3.3.x where sometimes, despite the ASVersion matching the correct SQL Sever version, and despite the fact BPM Connect operates as expected,  this warning still persists.    To solve the over sensitive warning, please apply this SQL patch  p_UI_ISBATCHRUN 1.5.sql.

This over sensitive warning has been solved in DBObjects 3.3.4.